Feedback and temperature monitoring connecon
ICN-M23 connector assignment
Resolvers
Contact Name Meaning
1 + Ref
Transformer windings
2 - Ref
3 +VCC ENP
Supply: Electronic nameplate
(Only for motors and inverters which support this
funcon)
4 + Cos
Stator windings cosine
5 - Cos
6 + Sin
Stator windings Sine
7 - Sin
8
Not assigned
9
10 Shield Encoder housing shield
11 +
Temperature monitoring: PT1000
12 -
ICN-M23 connector assignment
Incremental and SinCos absolute value encoder Hiperface©
Contact Name Meaning
1 B Track B / + SIN
2 A¯ Track A inverse / - COS
3 A Track A / + COS
4 + UB Supply +
5 GND Mass
6 Z¯ Zero track inverse / - RS485
7 Z Zero track / + RS485
8 Not assigned
9 B¯ Track B inverse/-SIN
10 Shield Encoder housing shield
11 +
Temperature monitoring: PT1000
12 -
Blower connecon
Pin assignment ICN-M17
Single−phase
Contact Name Meaning
PE PE PE conductor
1 U1
Fan
2 U2
3
Not assigned
4
5
6
Pin assignment ICN-M17
3-phase
Contact Name Meaning Illustraon
PE PE PE conductor
1 V Power phase U
2 Not assigned
3 V Power phase V
4
Not assigned
5
6 W Power phase W
Electrical installaon
Motor connecon
Connecon via ICN connector
43