Parameter
Address Name / seng range / [default seng] Informaon
0x2B09:001
(P315.01)
Slip compensaon: Gain
(Slip c
ompens.: Slip: gain)
-200.00 ... [100.00] ... 200.00 %
Adjustment in percent of the slip calculated.
•
For instance required for deviaons of the real motor data from the
nameplate data.
•
A seng of 100 % corresponds to the rated slip of the machine in the
nominal operang point.
0x2B09:002
(P315.02)
Slip compensaon: Filter me
(Slip compens.: Filter me)
1 ... [100] ... 6000 ms
Filter me for the slip compensaon.
•
The pr
eset
lter me is adapted to typical motors.
0x2C02:004
(P351.04)
Motor parameter (ASM): Slip frequency
(ASM mot
or par.: Slip frequency)
•
Read only: x.x Hz
Display of the rated slip determined.
0x2DE0:010 V/f behavior
0 ... [0] ... 65535
•
Seng can only be changed if the inverter is
disabled.
•
Fr
om version 05.03
Calculaon source for slip in the V/f control.
Bit 0 Slip compensaon via equivalent circuit
diagram
Bit 0 = 0: calculaon via motor data label (standard).
Bit 0 = 1: calculaon of magnesing current based on equivalent circuit
diagram (response <= SW 05.02.00).
Conguring the motor control
V
/f characterisc control for asynchronous motor (VFC open loop)
Set slip compensaon
149