Performing opmizaon with engineering tool
The following ow diagram shows the opmizaon process with an engineering tool
(e. g. »E
ASY Starter«):
b)
e)
Yes
No
Yes
Yes
NoNo
No
End
of the motor (non-energised)
Automatic calibration
d)
speed controller are initialised
Only motor and
b)
of the motor (energized)
Automatic identification
c)
coupling to the motor
• Mechanical load and its
Set manually:
coupling to the motor
• Mechanical load and its
• Motor control type
the motor nameplate)
• Motor data (e.g. according to data on
Set manually:
Lenze motor
connected?
possible?
(energized)
Identification
possible?
(energized)
Identification
required?
speed controller
Adjustment of
is selected
Motor from motor catalogue
a)
Start
Yes
a) The relevant motor data must be set rst. You benet from very precise motor equivalent circuit diagram data by selecng the motor from
the mot
or catalogue.
4Select motor from motor catalog ^ 40
b) Manually set the motor data in accordance with the manufacturer's informaon / motor data sheet when a third-party motor is connected
t
o the inverter.
4Manual seng of the motor data^ 41
c) The speed controller must be rst
reinialised alone if the load adjustment in the opmized system has changed.
4Tuning of the motor and the speed controller ^ 180
d) If the applicaon enables you to energise the system during the opmizaon procedure, carry out an automac idencaon. This
pr
ocedure results in the best possible parameter sengs.
4
Automac motor idencaon (energized) ^ 178
e) If the applicaon does not enable you to energise the system during the opmizaon procedure, carry out an automac calibraon.
4
Automac motor calibraon (non-energized) ^ 179
Conguring the motor control
Opons for opmizing the control loops
176