Performing opmizaon with keypad
Since there is no access with the keypad to the motor catalogue, rst the motor data must be
se
t manually with the keypad according to the manufacturer data/motor data sheet.
4Manual seng of the motor data ^ 41
The following ow diagram shows the opmisaon process with the keypad:
Yes
Yes No
No
End
d)
Automatic motor calibration
(non-energized)
c)
Automatic motor identification
(energized)
• Mechanical load and its coupling to the
motor
• Motor data (e.g. according to data on
the motor nameplate)
Set manually:
• Motor control type
a)
Lenze motor
connected?
Identification
(energized)
possible?
Start
a) Manually set the motor data in accordance with the manufacturer's informaon / motor data sheet when a third-party motor is
c
onnected to the inverter.
4Manual seng of the motor data^ 41
c) If the
applicaon enables you to energise the system during the opmizaon procedure, carry out an automac idencaon. This
procedure results in the best possible parameter sengs.
4
Automac motor idencaon (energized)^ 178
d) If the applicaon does not enable you to energise the system during the opmizaon procedure, carry out an automac calibraon.
4
Automac motor calibraon (non-energized)^ 179
Conguring the motor control
Opons for opmizing the control loops
177