Address Name / seng range / [default seng] Informaon
0x2637:002
(P431.02)
Analog input 2: Min frequency value
(Analog input 2: AI2 fr
eq @ min)
-1000.0 ... [0.0] ... 1000.0 Hz
Scaling of the input signal to the frequency value.
•
Direcon of rotaon according to sign.
•
The standard setpoint source for operang mode 0x6060 (P301.00) =
"MS: Velocity mode [-2]" is selected in 0x2860:001 (P201.01).
4
Conguring the frequency control ^ 64
0x2637:003
(P431.03)
Analog input 2: Max frequency value
(Analog input 2: AI2 fr
eq @ max)
Device for 50-Hz mains: -1000.0 ... [50.0] ... 1000.0 Hz
Device for 60-Hz mains: -1000.0 ... [60.0] ... 1000.0 Hz
0x2637:004
(P431.04)
Analog input 2: Min PID value
(Analog input 2: AI2 PID @ min)
-300.00 ... [0.00] ... 300.00
PID unit
Scaling of the input signal to the PID value.
•
The standard setpoint source for the reference value of PID control is
selected in 0x2860:002 (P201.02).
4Conguring the process controller ^ 98
0x2637:005
(P431.05)
Analog input 2: Max PID value
(Analog input 2: AI2 PID @ ma
x)
-300.00 ... [100.00] ... 300.00 PID unit
0x2637:006
(P431.06)
Analog input 2: Filter me
(Analog input 2: AI2 lter me)
0 ... [10] ... 10000 ms
PT1 me constant for low-pass lter.
•
B
y the use of a low-pass lter, the impacts of noise to an analog signal
c
an be minimised.
•
For an opmum lter eect, rst the noise frequency has to be
determined. The me constant then has to be set so that it equals the
reciprocal value of the double frequency.
0x2637:007
(P431.07)
Analog input 2: Dead band
(Analog input 2: AI2 dead band)
0.0 ... [0.0] ... 100.0 %
Oponal seng of a dead band that is placed symmetrically around the
frequency zero point.
•
If the analog input value is within the dead band, the output value for
the motor control is set to "0".
•
100 % = maximum value of analog input (0x2636:003 (P430.03),
0x2636:005 (P430.05), 0x2636:012 (P430.12))
•
Example: Dead band 10 % of 50 Hz: -10 V … 10 V Dead band -5 Hz …
5 Hz, 0 … 10 V Dead band 0 Hz … 5 Hz
0x2637:008
(P431.08)
Analog input 2: Monitoring threshold
(Analog input 2: AI2 monit.level)
-100.0 ... [0.0] ... 100.0 %
Monitoring threshold for analog input 2.
•
100 % = 10 V (with conguraon as voltage input)
•
100 % = 20 mA (with conguraon as current loop)
Excepon: In the case of a congured input range 4...20 mA (0x2636:001
[4]), the monitoring is triggered at 2 mA with a monitoring threshold of
0.0 %.
0x2637:009
(P431.09)
Analog input 2: Monitoring condion
(Analog input 2: Monitoring cond.)
Monitoring condion for analog input 2.
•
If the select
ed condion is met, the "Error of analog input 2 acve
[82]" trigger is set to TRUE. The trigger can be assigned to a funcon
or a digital output.
•
If the selected condion is met for at least 500 ms, the error response
set in 0x2637:010 (P431.10) takes place.
0 Input value < trigger threshold
1 Input value > trigger threshold
0x2637:010
(P431.10)
Analog input 2: Error response
(Analog input 2: AI2 error resp.)
Error response for analog input 2.
•
The selected response takes place if the monitoring condion selected
in 0x2637:009 (P431.09) is met for at least 500 ms.
Associated error code:
•
28802 | 0x7082 - Analog input 2 fault
0 No response
4Err
or types ^ 285
1 Warning
2 Trouble
3 Fault
0x2637:011
(P431.11)
Analog input 2: Min torque value
(Analog input 2: Min. t
orque)
-400.0 ... [0.0] ... 400.0 %
•
From version 03.00
Scaling of the input signal to the torque value.
•
100 % = permissible maximum torque 0x6072 (P326.00)
•
Direcon of rotaon according to sign.
•
The standard setpoint source for operang mode 0x6060 (P301.00) =
"MS: Torque mode [-1]" is selected in 0x2860:003 (P201.03).
4Conguring the torque control ^ 129
0x2637:012
(P431.12)
Analog input 2: Max torque value
(Analog input 2: Max. torque)
-400.0 ... [100.0] ... 400.0 %
•
From version 03.00
I/O extensions and control connecons
Congure analog inputs
Analog input 2