0
STO
Fig. 14: Safety funcon STO
Funconal sequence and error response have no adjustable parameters.
Truth table
Safe input / channel Inverter Inverter status word CiA402 status word
SIA SIB Device status Bit 55 Bit 155 Object 0x6041, bit 15
LOW LOW STO acve 1 1 0
LOW HIGH
Impermissible state
1 0 0
HIGH LOW 1 0 0
HIGH HIGH Drive enabled 0 0 1
If the GS connecon is interrupted or in case of a short circuit/short circuit of GS
to SIA/SIB, STO is acve.
Acceptance
The machine manufacturer must check and prove the operability of the safety funcons used.
The machine manufacturer must authorise a person with experse and knowledge of the
safety funcons to carry out the test.
The test result of every safety funcon must be documented and signed by the inspector.
A complete test comprises the following:
Documenng the plant including the safety funcons:
Creang an overview screen of the plant.
Describing the plant.
Describing the safety equipment.
Documenng the safety funcons used.
Checking the funcon of the safety funcons used.
Preparing the test report:
Documenng the funconal test.
Checking the parameters.
Signing the test report.
Preparing the appendix with test records:
Protocols for the plant
External recording
The tester must repeat the test aer each change and record the results in the
test report.
Product extensions
Funconal safety
Acceptance
236