Fusing data
Inverter i550-C15/400-3 i550-C18/400-3 i550-C22/400-3 i550-C30/400-3
Cable installaon in compliance
with
EN 60204-1
without mains choke
Circuit breaker
Characteriscs B -
Max. rated current A 63 - - -
Fuse
Characteriscs gG/gL or gRL -
Max. rated current A 63 - - -
with mains choke
Circuit breaker
Characteriscs B
Max. rated current A 63 63 63 80
Fuse
Characteriscs gG/gL or gRL
Max. rated current A 63 63 63 80
Earth-leakage circuit breaker
3-phase mains connecon ≥ 300 mA, type B
Fusing data
Inverter i550-C37/400-3 i550-C45/400-3
Cable installaon in compliance
with
EN 60204-1
without mains choke
Circuit breaker
Characteriscs -
Max. rated current A - -
Fuse
Characteriscs -
Max. rated current A - -
with mains choke
Circuit breaker
Characteriscs B
Max. rated current A 100 125
Fuse
Characteriscs gG/gL or gRL
Max. rated current A 100 125
Earth-leakage circuit breaker
3-phase mains connecon ≥ 300 mA, type B
Technical data
3-phase mains connecon 400 V "Light Duty"
Fusing data