Inverter i550-C1.5/400-3 i550-C2.2/400-3 i550-C3.0/400-3 i550-C4.0/400-3
Rated power kW P
N
1.5 2.2 3 4
Rated power hp P
N
2 3 4 5
Mains voltage range 3/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
Output voltage 3 AC 0-400/480 V
Rated mains current
without mains choke A I
r, AC
4.5 6.5 8 10.5
with mains choke A I
r, AC
3.1 4.4 5.8 7.5
Apparent output power kVA A
ON
2.6 3.8 4.9 6.4
Rated output current
2 kHz A I
OUT
3.5 4.8 6.3 8.2
4 kHz A I
OUT
3.5 4.8 6.3 8.2
8 kHz A I
OUT
3.5 4.8 6.3 8.2
16 kHz A I
OUT
2.3 3.2 4.2 5.5
Power loss
2 kHz W 45 62 79 102
4 kHz W 48 66 85 110
8 kHz W 61 85 110 140
16 kHz W 61 85 109 140
at inverter disablecontroller
inhibit
W 6 6 6 6
Overcurrent cycle 180 s
Max. output current A I
max, out
5.3 7.2 9.5 12.3
Overload me s t
ol
60 60 60 60
Recovery me s t
re
120 120 120 120
Max. output current during the
recovery me
A 2.6 3.6 4.8 6.2
Overcurrent cycle 15 s
Max. output current A I
max, out
7 9.6 12.6 16.4
Overload me s t
ol
3 3 3 3
Recovery me s t
re
12 12 12 12
Max. output current during the
recovery me
A 2.6 3.6 4.7 6.2
Cyclic mains switching 3 mes per minute
Brake chopper
Max. output current A I
max, 1
4.3 4.3 9.5 16.6
Min. brake resistance Ω R
min
180 150 82 47
Max. motor cable length shielded
without EMC category m 50 50 100 100
Category C1 (2 kHz, 4 kHz, 8
kHz)
m - - - -
Category C2 (2 kHz, 4 kHz, 8
kHz)
m 20 20 20 20
Category C3 (2 kHz, 4 kHz, 8
kHz)
m 35 35 35 35
Weight kg 1.35 1.35 2.3 2.3
Weight lb 3 3 5 5
Technical data
3-phase mains connecon 480 V
Rated data
158