EasyManua.ls Logo

Lenze i550 Series - Page 160

Lenze i550 Series
264 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Inverter i550-C18/400-3 i550-C22/400-3 i550-C30/400-3 i550-C37/400-3
Rated power kW P
N
18.5 22 30 37
Rated power hp P
N
25 30 40 50
Mains voltage range 3/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
Output voltage 3 AC 0-400/480 V
Rated mains current
without mains choke A I
r, AC
40.3 47.4 - -
with mains choke A I
r, AC
30 35.3 45.7 57
Apparent output power kVA A
ON
27 32 41 51
Rated output current
2 kHz A I
OUT
34 40.4 52 65
4 kHz A I
OUT
34 40.4 52 65
8 kHz A I
OUT
34 40.4 52 65
16 kHz A I
OUT
22.6 26.9 34.6 43.3
Power loss
2 kHz W 420 491 639 790
4 kHz W 450 520 680 840
8 kHz W 570 670 880 1100
16 kHz W 581 680 884 1095
at inverter disablecontroller
inhibit
W 18 18 25 25
Overcurrent cycle 180 s
Max. output current A I
max, out
51 61 78 98
Overload me s t
ol
60 60 60 60
Recovery me s t
re
120 120 120 120
Max. output current during the
recovery me
A 25.5 30 39 49
Overcurrent cycle 15 s
Max. output current A I
max, out
68 81 104 130
Overload me s t
ol
3 3 3 3
Recovery me s t
re
12 12 12 12
Max. output current during the
recovery me
A 25.5 30 39 49
Cyclic mains switching 3 mes per minute
Brake chopper
Max. output current A I
max, 1
52 52 98 98
Min. brake resistance Ω R
min
15 15 7.5 7.5
Max. motor cable length shielded
without EMC category m 100 100 100 100
Category C1 (2 kHz, 4 kHz, 8
kHz)
m - - - -
Category C2 (2 kHz, 4 kHz, 8
kHz)
m 20 20 20 20
Category C3 (2 kHz, 4 kHz, 8
kHz)
m 35 35 35 35
Weight kg 10.3 10.3 17.2 17.2
Weight lb 23 23 38 38
Technical data
3-phase mains connecon 480 V
Rated data