Aribute
(Instance ID)
Name Info / parameter
Assembly output object instances according to AC Drive prole
20 Basic Speed Control Output LSB of the AC Drive control word 0x400B:001 (P592.01) (some bits are masked)
40x400B:004 (P592.04) Network setpoint speed
21 Extended Speed Control Output LSB of the AC Drive control word 0x400B:001 (P592.01)
40x400B:004 (P592.04) Network setpoint speed
22 Speed and Torque Control Output LSB of the AC Drive control word 0x400B:001 (P592.01) (some bits are masked)
40x400B:004 (P592.04) Network setpoint speed
40x400B:008 (P592.08) Torque mode setpoint
23 Extended Speed and Torque Control Out-
put
LSB of the AC Drive control word 0x400B:001 (P592.01)
40x400B:004 (P592.04) Network setpoint speed
40x400B:008 (P592.08) Torque mode setpoint
Assembly input object instances according to the AC Drive prole
70 Basic Speed Control Input LSB of the AC Drive status word 0x400C:001 (P593.01) (some bits are masked)
40x400C:004 (P593.04) Motor speed
71 Extended Speed Control Input LSB of the AC Drive status word 0x400C:001 (P593.01)
40x400C:004 (P593.04) Motor speed
72 Speed and Torque Control Input LSB of the AC Drive status word 0x400C:001 (P593.01)
40x400C:004 (P593.04) Motor speed
40x400C:007 (P593.07) Torque scaled
73 Extended Speed and Torque Control
Input
LSB of the AC Drive status word 0x400C:001 (P593.01)
MSB Drive State of the AC Drive status word (mask bits 12 ... 15)
40x400C:004 (P593.04) Motor speed
40x400C:007 (P593.07) Torque scaled
Assembly object instances for customer specic conguraons
110 Custom Output Customised
The inverter must be registered with an EDS device descripon le in »RSLogix™
5000« to be able to assign data to these assembly object instances.
111 Custom Input
Conguring the network
AC drive prole
Customised conguraons
333