Display code Short designaon Default seng Seng range Address Category
P430.xx Analog input 1
P430.01 AI1 input range 0 ... 10 VDC [0] Selecon list 0x2636:001 general
P430.02 AI1 freq @ min 0.0 Hz -1000.0 ... 1000.0 Hz 0x2636:002 general
P430.03 AI1 freq @ max Device for 50-Hz mains:
50.0 Hz
Device for 60-Hz mains:
60.0 Hz
-1000.0 ... 1000.0 Hz 0x2636:003 general
P430.04 AI1 PID @ min 0.00 PID unit -300.00 ... 300.00 PID unit 0x2636:004 general
P430.05 AI1 PID @ max 100.00 PID unit -300.00 ... 300.00 PID unit 0x2636:005 general
P430.06 AI1 lter me 10 ms 0 ... 10000 ms 0x2636:006 general
P430.07 AI1 dead band 0.0 % 0.0 ... 100.0 % 0x2636:007 general
P430.08 AI1 monit.level 0.0 % -100.0 ... 100.0 % 0x2636:008 general
P430.09 Monitoring cond. IN < threshold [0] Selecon list 0x2636:009 general
P430.10 AI1 error resp. Fault [3] Selecon list 0x2636:010 general
P430.11 Min. torque 0.0 % -400.0 ... 400.0 % 0x2636:011 general
P430.12 Max. torque 100.0 % -400.0 ... 400.0 % 0x2636:012 general
P431.xx Analog input 2
P431.01 AI2 input range 0 ... 10 VDC [0] Selecon list 0x2637:001 general
P431.02 AI2 freq @ min 0.0 Hz -1000.0 ... 1000.0 Hz 0x2637:002 general
P431.03 AI2 freq @ max Device for 50-Hz mains:
50.0 Hz
Device for 60-Hz mains:
60.0 Hz
-1000.0 ... 1000.0 Hz 0x2637:003 general
P431.04 AI2 PID @ min 0.00 PID unit -300.00 ... 300.00 PID unit 0x2637:004 general
P431.05 AI2 PID @ max 100.00 PID unit -300.00 ... 300.00 PID unit 0x2637:005 general
P431.06 AI2 lter me 10 ms 0 ... 10000 ms 0x2637:006 general
P431.07 AI2 dead band 0.0 % 0.0 ... 100.0 % 0x2637:007 general
P431.08 AI2 monit.level 0.0 % -100.0 ... 100.0 % 0x2637:008 general
P431.09 Monitoring cond. IN < threshold [0] Selecon list 0x2637:009 general
P431.10 AI2 error resp. Fault [3] Selecon list 0x2637:010 general
P431.11 Min. torque 0.0 % -400.0 ... 400.0 % 0x2637:011 general
P431.12 Max. torque 100.0 % -400.0 ... 400.0 % 0x2637:012 general
P440.xx Analog output 1
P440.01 AO1 outp. range 0 ... 10 VDC [1] Selecon list 0x2639:001 general
P440.02 AO1 funcon Outp. frequency [1] Selecon list 0x2639:002 general
P440.03 AO1 min. signal 0 -2147483648 ... 2147483647 0x2639:003 general
P440.04 AO1 max. signal 1000 -2147483648 ... 2147483647 0x2639:004 general
P441.xx Analog output 2
P441.01 AO2 outp. range 0 ... 10 VDC [1] Selecon list 0x263A:001 Appl. I/O
P441.02 AO2 funcon Motor current [5] Selecon list 0x263A:002 Appl. I/O
P441.03 AO2 min. signal 0 -2147483648 ... 2147483647 0x263A:003 Appl. I/O
P441.04 AO2 max. signal 1000 -2147483648 ... 2147483647 0x263A:004 Appl. I/O
P450.xx Freq. presets
P450.01 Freq. preset 1 20.0 Hz 0.0 ... 599.0 Hz 0x2911:001 general
P450.02 Freq. preset 2 40.0 Hz 0.0 ... 599.0 Hz 0x2911:002 general
P450.03 Freq. preset 3 Device for 50-Hz mains:
50.0 Hz
Device for 60-Hz mains:
60.0 Hz
0.0 ... 599.0 Hz 0x2911:003 general
P450.04 Freq. preset 4 0.0 Hz 0.0 ... 599.0 Hz 0x2911:004 general
P450.05 Freq. preset 5 0.0 Hz 0.0 ... 599.0 Hz 0x2911:005 general
P450.06 Freq. preset 6 0.0 Hz 0.0 ... 599.0 Hz 0x2911:006 general
P450.07 Freq. preset 7 0.0 Hz 0.0 ... 599.0 Hz 0x2911:007 general
P450.08 Freq. preset 8 0.0 Hz 0.0 ... 599.0 Hz 0x2911:008 general
P450.09 Freq. preset 9 0.0 Hz 0.0 ... 599.0 Hz 0x2911:009 general
* Default seng depending on the size.