Display code Short designaon Default seng Seng range Address Category
P515.06 Timeout ExplMsg Warning [1] Selecon list 0x2859:006 EtherNet/IP
P515.07 Timeout Comm. Warning [1] Selecon list 0x2859:007 EtherNet/IP
P515.xx Modbus monit.
P515.01 Resp. Time-out Fault [3] Selecon list 0x2858:001 Modbus RTU
P515.02 Time-out me 2.0 s 0.0 ... 300.0 s 0x2858:002 Modbus RTU
P515.xx MBTCP monitoring
P515.03 Cong error Trouble [2] Selecon list 0x2859:003 Modbus TCP
P515.04 Init error Trouble [2] Selecon list 0x2859:004 Modbus TCP
P515.07 React t-out netw Warning [1] Selecon list 0x2859:007 Modbus TCP
P515.08 React t-out mast Fault [3] Selecon list 0x2859:008 Modbus TCP
P515.09 Reac t-out kp-al Fault [3] Selecon list 0x2859:009 Modbus TCP
P515.xx PROFIBUS monit.
P515.01 WD elapsed Trouble [2] Selecon list 0x2859:001 PROFIBUS
P515.02 Data exch.exited No response [0] Selecon list 0x2859:002 PROFIBUS
P515.03 Invalid cong Trouble [2] Selecon list 0x2859:003 PROFIBUS
P515.04 Init. error Trouble [2] Selecon list 0x2859:004 PROFIBUS
P515.05 Inval. proc.data Trouble [2] Selecon list 0x2859:005 PROFIBUS
P515.xx PROFINET monit.
P515.01 WD elapsed Trouble [2] Selecon list 0x2859:001 PROFINET
P515.02 Data exch.exited No response [0] Selecon list 0x2859:002 PROFINET
P515.03 Invalid cong Trouble [2] Selecon list 0x2859:003 PROFINET
P515.04 Init. error Trouble [2] Selecon list 0x2859:004 PROFINET
P515.05 Inval. proc.data Trouble [2] Selecon list 0x2859:005 PROFINET
P516.00 CANopen status - - (Read only) 0x2308 CANopen
P516.00 EtherCAT status - - (Read only) 0x2368 EtherCAT
P516.00 CIP module stat. - - (Read only) 0x23A8 EtherNet/IP
P516.00 MBTCP modul. stat - - (Read only) 0x23B8 Modbus TCP
P516.xx PROFIBUS Status
P516.01 Bus status - - (Read only) 0x2348:001 PROFIBUS
P516.02 Watchdog status - - (Read only) 0x2348:002 PROFIBUS
P516.00 PROFINET status - - (Read only) 0x2388 PROFINET
P517.00 CAN contr.status - - (Read only) 0x2309 CANopen
P517.00 EtherCAT error - - (Read only) 0x2369 EtherCAT
P517.00 EtherN/IP status - - (Read only) 0x23A9 EtherNet/IP
P517.00 MBTCP netw stat - - (Read only) 0x23B9 Modbus TCP
P517.00 PROFIBUS error - - (Read only) 0x2349 PROFIBUS
P517.xx PROFINET error
P517.01 Error 1 - - (Read only) 0x2389:001 PROFINET
P517.02 Error2 - - (Read only) 0x2389:002 PROFINET
P518.00 CAN errorcounter - - (Read only) 0x230B CANopen
P519.xx Port diagnoscs
P519.01 Port 1 - - (Read only) 0x23A5:001 EtherNet/IP
P519.02 Port 2 - - (Read only) 0x23A5:002 EtherNet/IP
P520.xx Cons. heartbeat
P520.00 Highest subindex - - (Read only) 0x1016 CANopen
P520.01 Cons. heartbeat1 0x00000000 0x00000000 ... 0x00FFFFFF 0x1016:001 CANopen
P520.02 Cons. heartbeat2 0x00000000 0x00000000 ... 0x00FFFFFF 0x1016:002 CANopen
P520.03 Cons. heartbeat3 0x00000000 0x00000000 ... 0x00FFFFFF 0x1016:003 CANopen
P520.04 Cons. heartbeat4 0x00000000 0x00000000 ... 0x00FFFFFF 0x1016:004 CANopen
P522.00 Prod. heartbeat 0 ms 0 ... 65535 ms 0x1017 CANopen
P530.xx Para. mapping
P530.01 ... 24 Parameter 1 ... Parameter
24
0x00000000 0x00000000 ... 0xFFFFFF00 0x232B:001 ...
0x232B:024
Modbus RTU
P530.xx MBTCP param.mapp
* Default seng depending on the size.