Address Designaon Default seng Category Data type Factor A M
0x2DAE:011 Sequencer diagnoscs: PID setpoint x.xx PID unit (Read only) Sequencer I16 100 - -
0x2DAE:012 Sequencer diagnoscs: Torque setpoint x.x % (Read only) Sequencer I16 10 - -
0x282B:009 Inverter diagnoscs: Actual frequency setpoint x.x Hz (Read only) general I16 10 - -
0x2DD1:001 Motor currents: Actual D-current (id) x.xx A (Read only) MCTRL I32 100 O t
0x2DD1:002 Actual Q-current (iq) x.xx A (Read only) general I32 100 O t
0x2DD1:003 Setpoint D-current (id) x.xx A (Read only) general I32 100 O t
0x2DD1:004 Motor currents: Setpoint Q-current (iq) x.xx A (Read only) MCTRL I32 100 O t
0x2DD1:005 Motor currents: Motor current (Ie) x.xx A (Read only) MCTRL I32 100 O t
0x2DD3:003 Speed setpoint limited x rpm (Read only) MCTRL I32 1 O t
0x2DD5 Torque setpoint x.xx Nm (Read only) general I32 100 - t
0x2DDD
(P100.00)
Output frequency x.x Hz (Read only) general I16 10 O t
0x2DDF:001 Axis informaon: Rated current x.xx A (Read only) general U16 100 O t
0x2DDF:002 Axis informaon: Maximum current x.xx A (Read only) general U16 100 O t
0x2DE0:009 Motor idencaon sengs 0 general U16 1 PC -
0x2DE0:010 Slip compensaon sengs 0 general U16 1 PC -
0x4002
(P702.00)
Speed display scaling 0.00 general U16 100 P -
0x4003
(P413.00)
MOP starng mode Last value [0] general U8 1 P -
0x4004:001
(P414.01)
MOP starng values: Frequency 0.0 Hz general U16 10 P -
0x4004:002
(P414.02)
MOP starng values: PID value 0.00 PID unit general I16 100 P -
0x4004:003
(P414.03)
MOP starng values: Torque 0.0 % general U16 10 P -
0x4005
(P412.00)
Frequency threshold 0.0 Hz general U16 10 P -
0x4006:001
(P710.01)
Load loss detecon: Threshold 0.0 % general U16 10 P -
0x4006:002
(P710.02)
Load loss detecon: Delay me 0.0 s general U16 10 P -
0x4006:003
(P710.03)
Load loss detecon: Error response No response [0] general U8 1 P -
0x4007:001 Heavy load monitoring: Error threshold 200.0 % general U16 10 P -
0x4007:002 Heavy load monitoring: Delay me 3.0 s general U16 10 P -
0x4007:003 Heavy load monitoring: Error response No response [0] general U8 1 P -
0x4008:001
(P590.01)
Process input words: NetWordIN1 0x0000 general U16 1 HK r
0x4008:002
(P590.02)
Process input words: NetWordIN2 0x0000 general U16 1 HK r
0x4008:003
(P590.03)
Process input words: NetWordIN3 0.0 % general U16 10 K r
0x4008:004
(P590.04)
Process input words: NetWordIN4 0.0 % general U16 10 K r
0x4008:005
(P590.05)
Process input words: NetWordIN5 0.0 % general I16 10 OK r
0x4009:001 MOP values saved: Frequency x.x Hz (Read only) general U16 10 - t
0x4009:002 MOP values saved: PID value x.xx PID unit (Read only) general I16 100 - t
0x4009:003 MOP values saved: Torque x.x % (Read only) general U16 10 - t
0x4009:004 MOP values saved: Frequency setpoint x.x Hz (Read only) general I16 10 - -
0x4009:005 MOP values saved: PID setpoint x.xx PID unit (Read only) general I16 100 - -
0x4009:006 MOP values saved: Torque setpoint x.x % (Read only) general I16 10 - -
0x400A:001
(P591.01)
Process output words: NetWordOUT1 - (Read only) general U16 1 H t
0x400A:002
(P591.02)
Process output words: NetWordOUT2 - (Read only) general U16 1 - t
* Default seng depending on the size.
Appendix
Parameter aribute list
694