Address Designaon Default seng Category Data type Factor A M
0x400B:001
(P592.01)
Process input data: AC Drive control word 0x0000 general U16 1 OH
K
r
0x400B:002
(P592.02)
Process input data: LECOM control word 0x0000 general U16 1 OH
K
r
0x400B:003
(P592.03)
Process input data: Network setpoint frequency
(0.1)
0.0 Hz general U16 10 OK r
0x400B:004
(P592.04)
Process input data: Network setpoint speed 0 rpm general U16 1 OK r
0x400B:005
(P592.05)
Process input data: Network setpoint frequency
(0.01)
0.00 Hz general U16 100 OK r
0x400B:006
(P592.06)
Process input data: Velocity mode setpoint 0.0 Hz general I16 10 OK r
0x400B:007
(P592.07)
Process input data: PID setpoint 0.00 PID unit general I16 100 OK r
0x400B:008
(P592.08)
Process input data: Torque mode setpoint 0 Nm general I16 1 OK r
0x400B:009
(P592.09)
Process input data: Torque scaling 0 general I8 1 OK r
0x400B:010 AC Drive mode Speed control (open
loop) [1]
EtherNet/IP U8 1 OI
K
-
0x400B:011
(P592.11)
Process input data: PID feedback 0.00 PID unit general I16 100 OK r
0x400B:012
(P592.12)
Process input data: Network setpoint frequency
[0.02Hz]
0 Hz general I16 50 K r
0x400B:013
(P592.13)
Process input data: Network frequency setpoint
[+/-16384]
0 general I16 1 O r
0x400C:001
(P593.01)
Process output data: AC Drive status word - (Read only) general U16 1 - t
0x400C:002
(P593.02)
Process output data: LECOM status word - (Read only) general U16 1 - t
0x400C:003
(P593.03)
Process output data: Frequency (0.1) x.x Hz (Read only) general U16 10 - t
0x400C:004
(P593.04)
Process output data: Motor speed x rpm (Read only) general U16 1 - t
0x400C:005
(P593.05)
Process output data: Drive status - (Read only) general U16 1 - t
0x400C:006
(P593.06)
Process output data: Frequency (0.01) x.xx Hz (Read only) general U16 100 - t
0x400C:007
(P593.07)
Process output data: Torque scaled - (Read only) general I16 1 - t
0x400C:008
(P593.08)
Process output data: Frequency [0.02 Hz] Hz (Read only) general I16 50 - t
0x400C:009
(P593.09)
Process output data: Frequency [+/-16384] - (Read only) general I16 1 O t
0x400D
(P101.00)
Scaled actual value x Units (Read only) general I16 1 O t
0x400E:001
(P505.01)
NetWordIN1 funcon: Bit 0 Not acve [0] general U8 1 PC -
0x400E:002
(P505.02)
NetWordIN1 funcon: Bit 1 Not acve [0] general U8 1 PC -
0x400E:003
(P505.03)
NetWordIN1 funcon: Bit 2 Acvate quick stop [3] general U8 1 PC -
0x400E:004
(P505.04)
NetWordIN1 funcon: Bit 3 Not acve [0] general U8 1 PC -
0x400E:005
(P505.05)
NetWordIN1 funcon: Bit 4 Run forward (CW) [8] general U8 1 PC -
0x400E:006
(P505.06)
NetWordIN1 funcon: Bit 5 Acvate preset (bit 0)
[18]
general U8 1 PC -
* Default seng depending on the size.