Address Designaon Default seng Category Data type Factor A M
0x400E:007
(P505.07)
NetWordIN1 funcon: Bit 6 Acvate preset (bit 1)
[19]
general U8 1 PC -
0x400E:008
(P505.08)
NetWordIN1 funcon: Bit 7 Reset error [4] general U8 1 PC -
0x400E:009
(P505.09)
NetWordIN1 funcon: Bit 8 Not acve [0] general U8 1 PC -
0x400E:010
(P505.10)
NetWordIN1 funcon: Bit 9 Acvate DC braking [5] general U8 1 PC -
0x400E:011
(P505.11)
NetWordIN1 funcon: Bit 10 Not acve [0] general U8 1 PC -
0x400E:012
(P505.12)
NetWordIN1 funcon: Bit 11 Not acve [0] general U8 1 PC -
0x400E:013
(P505.13)
NetWordIN1 funcon: Bit 12 Reverse rotaonal direc-
on [13]
general U8 1 PC -
0x400E:014
(P505.14)
NetWordIN1 funcon: Bit 13 Not acve [0] general U8 1 PC -
0x400E:015
(P505.15)
NetWordIN1 funcon: Bit 14 Not acve [0] general U8 1 PC -
0x400E:016
(P505.16)
NetWordIN1 funcon: Bit 15 Not acve [0] general U8 1 PC -
0x4016:003 Digital output 1: Cutout delay 0.000 s general U16 1000 P -
0x4016:004 Digital output 1: Switch-on delay 0.000 s general U16 1000 P -
0x4016:005 Digital output 1: Terminal state - (Read only) general U8 1 - -
0x4016:006 Digital output 1: Trigger signal state - (Read only) general U8 1 - -
0x4017:003 Digital output 2: Cutout delay 0.000 s Appl. I/O U16 1000 P -
0x4017:004 Digital output 2: Switch-on delay 0.000 s Appl. I/O U16 1000 P -
0x4017:005 Digital output 2: Terminal state - (Read only) Appl. I/O U8 1 - -
0x4017:006 Digital output 2: Trigger signal state - (Read only) Appl. I/O U8 1 - -
0x4018:003 Relay: Switch-o delay 0.000 s general U16 1000 P -
0x4018:004 Relay: Switch-on delay 0.000 s general U16 1000 P -
0x4018:005 Relay: Relay state - (Read only) general U8 1 - -
0x4018:006 Relay: Trigger signal state - (Read only) general U8 1 - -
0x4018:007 Relay: Switching cycles - (Read only) general U32 1 - -
0x401F:001
(P121.01)
Current setpoint x.xx PID unit (Read only) general I16 100 O t
0x401F:002
(P121.02)
Current process variable x.xx PID unit (Read only) general I16 100 O t
0x401F:003
(P121.03)
Status - (Read only) general U8 1 O t
0x401F:004 PID control value x.x Hz (Read only) general I16 10 - -
0x401F:005 PID Feedforward value x.x Hz (Read only) general I16 10 - -
0x401F:006 PID output value x.x Hz (Read only) general I16 10 - t
0x401F:007 PID error value x.xx PID unit (Read only) general I32 100 - -
0x4020:001
(P600.01)
Process controller setup (PID): Operang mode Inhibited [0] general U8 1 P -
0x4020:002
(P600.02)
Process controller setup (PID): PID process variable Analog input 1 [1] general U8 1 P -
0x4020:003
(P600.03)
Process controller setup (PID): Closed-loop control-
led speed range
100 % general U16 1 P rt
0x4020:004
(P600.04)
Process controller setup (PID): Speed feedforward
control source
Without speed addion
[0]
general U8 1 P -
0x4020:005
(P600.05)
Process controller setup (PID): Min speed limit -100.0 % general I16 10 P -
0x4020:006
(P600.06)
Process controller setup (PID): Max speed limit 100.0 % general I16 10 P -
0x4021:001
(P606.01)
PID speed operaon: Acceleraon me 1.0 s general U16 10 P -
* Default seng depending on the size.