Inverter i550-C1.5/400-3 i550-C2.2/400-3 i550-C3.0/400-3 i550-C4.0/400-3
Rated power kW 1.5 2.2 3 4
Mains voltage range 3/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
Rated mains current
without mains choke A 5.4 7.8 9.6 12.5
with mains choke A 3.7 5.3 6.9 9
Apparent output power kVA 2.6 3.6 4.9 6.4
Output current
2 kHz A 3.9 5.6 7.3 9.5
4 kHz A 3.9 5.6 7.3 9.5
8 kHz A 3.9 5.6 7.3 9.5
16 kHz A 2.6 3.7 4.9 6.3
Power loss
4 kHz W 48 66 85 110
8 kHz W 61 85 110 140
at controller inhibit W 6 6 6 6
Overcurrent cycle 180 s
Max. output current A 5.9 8.4 11 14.3
Overload me s 60 60 60 60
Recovery me s 120 120 120 120
Max. output current during the
r
ecovery me
A
2.9 4.2 5.5 7.1
Overcurrent cycle 15 s
Max. output current A 7.8 11.2 14.6 19
Overload me s 3 3 3 3
Recovery me s 12 12 12 12
Max. output current during the
recovery me
A
2.9 4.2 5.5 7.1
Brake chopper
Max. output current A 4.3 4.3 9.5 16.6
Min. brake resistance Ω 180 150 82 47
Max. motor cable length shielded
without EMC category m 50
Category C1 (2 kHz, 4 kHz, 8 kHz) m -
Category C2 m 20
Weight kg 1.35 2.3
Technical data
3-phase mains connecon 400 V
Ra
ted data
50