EasyManua.ls Logo

Lenze i550 - Page 63

Lenze i550
141 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Inverter i550-C45/400-3 i550-C55/400-3 i550-C75/400-3
Rated power kW 45 55 75
Mains voltage range 3/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
Rated mains current
without mains choke A - - -
with mains choke A 66.7 83 113
Apparent output power kVA 60 75 100
Output current
2 kHz A 77 96 124
4 kHz A 77 96 124
8 kHz A 77 96 124
16 kHz A 51.4 64 82.7
Power loss
4 kHz W 980 1210 1640
8 kHz W 1280 1580 2140
at controller inhibit W 25 30 30
Overcurrent cycle 180 s
Max. output current A 116 144 186
Overload me s 60 60 60
Recovery me s 120 120 120
Max. output current during the
r
ecovery me
A
58 72 93
Overcurrent cycle 15 s
Max. output current A 154 192 248
Overload me s 3 3 3
Recovery me s 12 12 12
Max. output current during the
recovery me
A
58 72 93
Brake chopper
Max. output current A 98 166 166
Min. brake resistance Ω 8 4.7 4.7
Max. motor cable length shielded
without EMC category m 100
Category C1 (2 kHz, 4 kHz, 8 kHz) m -
Category C2 m 20
Weight kg 17.2 24
Technical data
3-phase mains connecon 480 V
Ra
ted data
63

Table of Contents

Other manuals for Lenze i550