Mechanical ins
tallaon
Important notes
Measures for cooling during operaon
Ensur
e unimpeded venlaon of cooling air and outlet of exhaust air.
If the cooling air is polluted (u, (conducve) dust, soot, grease, aggressive gases), take
adequate countermeasures.
Install lters.
Arrange for regular cleaning of the lters.
Use air condioners with hermec separaon of the inside and outside air of the
control cabinet.
If required, implement a separate air guide.
Mounng of the supplier
s and axes
St
andard mounng: Mount the supplier to the le of the axis system.
For mounng to the right of the axis system, the swivel hooks for the busbar system must
be relocated.
The DC infeed adapter i700 E70AZEVE001 can be connected to the le or right side of
suppliers or axes.