Axis i750-C11/400-3 i750-C15/400-3
Rated power P
r
ated
kW 11 15
Rated power P
rated
hp 15 20
DC- Eingangsspannungsbereich DC 460 V ... 620 V
DC- Eingangsbemessungsstrom
without mains choke A 44.6 59.2
with mains choke A 29.8 39.5
DC-
Eingangsbemessungsleistung
without mains choke kW 15.3 20.3
with mains choke kW 15.3 20.3
Output voltage V 3 AC 0 - 400
Apparent output power kVA 15 20
Rated output current
4 kHz A 24 32
8 kHz A 19.2 25.6
16 kHz A 14.4 19.2
Power loss
4 kHz W 290 390
8 kHz W 250 330
16 kHz W 280 360
Overcurrent cycle 180 s
Max. output current A 36 48
Overload me T
1
s 60 60
Recovery me T
2
s 120 120
Max. output current during the
r
ecovery me
A 18 24
Overcurrent cycle 15 s
Max. output current A 48 64
Overload me T
1
s 3 3
Recovery me T
2
s 12 12
Max. output current during the
r
ecovery me
A 18 24
Max. shielded motor cable
length
without EMC category m 50
Kategorie C1 (4 kHz, 8 kHz,16
kHz)
m -
Kategorie C2 (4 kHz, 8 kHz,16
kHz)
m -
Kategorie C3 (4 kHz, 8 kHz,16
kHz)
m -
Max. Unshielded motor cable
length
without EMC category m 100
Technical data
3-phase mains c
onnecon 400 V
Axes data