Address Designaon Default seng Data type Factor A M
0x2D40:003 Device
ulisaon ixt: Power unit error threshold x % (Read only) U16 1 X
0x2D40:004 Device ulisaon ixt: Device actual ulisaon x % (Read only) U16 1 X
0x2D40:005 Device ulisaon ixt: Device warning threshold 95 % U16 1 -
0x2D40:006 Device ulisaon ixt: Device error threshold x % (Read only) U16 1 X
0x2D40:007 Device ulisaon ixt: Actual total ulisaon x % (Read only) U16 1 X
0x2D40:008 Device ulisaon ixt: Total ulisaon warning
threshold
95 % U16 1 -
0x2D40:009 Device ulisaon ixt: Total ulisaon error threshold x % (Read only) U16 1 X
0x2D44:001 Overspeed monitoring: Threshold 8000 rpm U16 1 -
0x2D44:002 Overspeed monitoring: Response Fault > CiA402 [1] U8 -
0x2D45:001 Motor phase failure detecon: Response - Motor
phase 1
No response [0] U8 -
0x2D45:002 Motor phase failure detecon: Current threshold 5.0 % U8 10 -
0x2D45:003 Motor phase failure detecon: Voltage threshold 10.0 V U16 10 -
0x2D45:004 Motor phase failure detecon: Response - Motor
phase 2
No response [0] U8 -
0x2D46:001 Overcurrent monitoring: Threshold 5.4 A U16 10 -
0x2D46:002 Overcurrent monitoring: Response Fault > CiA402 [1] U8 -
0x2D48:002 PTC temperature sensor monitoring: Error response Fault > CiA402 [1] U8 -
0x2D49:001 Motor temperature monitoring: Temperature sensor
type
PT1000 [5] U8 -
0x2D49:002 Motor temperature monitoring: Response Fault > CiA402 [1] U8 -
0x2D49:003 Motor temperature monitoring: Warning threshold 145.0 °C I16 10 -
0x2D49:004 Motor temperature monitoring: Error threshold 155.0 °C I16 10 -
0x2D49:005 Motor temperature monitoring: Actual motor tem-
per
ature
x.x °C (Read only) I16 10 X
0x2D49:006 Motor temperature monitoring: Spec. characterisc
temperature grid point 1
25.0 °C I16 10 -
0x2D49:007 Motor temperature monitoring: Spec. characterisc
temperature grid point 2
150.0 °C I16 10 -
0x2D49:008 Motor temperature monitoring: Spec. characterisc
resistance grid point 1
1000 Ω I16 1 -
0x2D49:009 Motor temperature monitoring: Spec. characterisc
resistance grid point 2
2225 Ω I16 1 -
0x2D49:010 Motor temperature monitoring: Temperature sensor
feedback type
KTY83-110 [0] U8 -
0x2D49:011 Motor temperature monitoring: Motor temperature
(Motor encoder)
x.x °C (Read only) I16 10 X
0x2D49:012 Motor temperature monitoring: Motor temperature
(load encoder)
x.x °C (Read only) I16 10 X
0x2D4C:001 Thermisches Modell Motorauslastung (i²xt): Motor
ulisaon (i²xt)
60 s U16 1 -
0x2D4C:002 Thermisches Modell Motorauslastung (i²xt): Ther-
mal
me constant - laminaons
852 s U16 1 -
0x2D4C:003 Thermisches Modell Motorauslastung (i²xt): Wind-
ing inuence
27 % U8 1 -
0x2D4C:004 Thermisches Modell Motorauslastung (i²xt): Starng
value
0 % U16 1 -
0x2D4D:001 Motor ulisaon (i²xt) - specic characterisc: x1 =
n01/nN (n01 ~ 0)
0 % U16 1 -
0x2D4D:002 Motor ulisaon (i²xt) - specic characterisc: y1 =
i01/iN (x1)
100 % U16 1 -
0x2D4D:003 Motor ulisaon (i²xt) - specic characterisc: x2 =
n02/nN (n02 = limit reduced cooling)
0 % U16 1 -
0x2D4D:004 Motor ulisaon (i²xt) - specic characterisc: y2 =
i02/iN (x2)
100 % U16 1 -
0x2D4D:005 Motor ulisaon (i²xt) - specic
characterisc: x3 =
n03/nN (n03 = rated speed)
100 % U16 1 -
* Default seng depending on the size.