Power supply modules
Wiring
Terminal assignment
6
254
EDS94SPP101 EN 7.1
Mains
Terminal X111 Labelling Description
Fig. 6-10
L1
L2
L3
Connection of the mains phases L1, L2, L3
C
t
i
f
t
h
l
i
d
P
E
d
t
Connection for the supply-side PE conductor
Terminal X112 Labelling Description
Fig. 6-10
L1
L2
L3
Alternative connection at the bottom: mains phases L1, L2, L3
C
t
i
f
t
h
l
i
d
P
E
d
t
Connection for the supply-side PE conductor
Terminal data
Max. conductor cross-section Tightening torque
[mm
2
] [AWG] [Nm] [lb-in]
Device size 4:
Connection with ring
cable lug M8
50
(2 x 25)
1/0
-
8 71 SW13
Device size 5:
Connection with ring
cable lug M10
120
(2 x 50)
4/0
(2 x 1/0)
15 133 SW15
DC bus
Terminal X111 Labelling Description
Fig. 6-10
+UG
-UG
Connection of DC-bus voltage
Cables routed upwards
Terminal X112 Labelling Description
Fig. 6-10
+UG
-UG
Connection of DC-bus voltage
Cables routed downwards
Terminal data
Max. conductor cross-section Tightening torque
[mm
2
] [AWG] [Nm] [lb-in]
Device size 4:
Connection with ring
cable lug M8
70
(2 x 35)
2/0
-
8 71 SW13
Device size 5:
Connection with ring
cable lug M10
150
(2 x 70)
300 mcm
(2 x 2/0)
15 133 SW15