Safety instructions
Residual hazards, layout of safety instructions
1
EDK82MV371 DE/EN/FR 6.0
75
L
Residual hazards
Protection of persons
l Disconnect the controller before you start working on it/open it and
wait for at least 3 minutes since the power terminals U, V, W; BR1,
BR2 and pins of the FIF interface remain live for this time.
After you have opened the motec check whether the power
terminals L1, L2; U, V, W; BR1, BR2, relay outputs K11, K12, K14
and pins of the FIF interface are not live any more.
Even if the controller is disconnected from the mains, the relay
outputs K11, K12, K14 can carry dangerous voltage!
l If you use the not open−circuit protected function Selection of
direction of rotation" via the digital signal CW/CCW (C0007 = −0− ...
−13−, C0410/3 255):
In the event of an open circuit or failure of the control voltage, the
drive can change its direction of rotation.
l If you use the function "Flying−restart circuit" (C0142 = −2−, −3−) with
machines with a low moment of inertia and a minimum friction:
After controller enable in standstill, the motor can start for a short
time or change its direction of rotation for a short time.
l The motec heatsink temperature is > 60 °C:
Direct skin contact with the heatsink results in burnings.
Motor protection
l Depending on the controller settings, the connected motor can be
overheated:
For instance, longer DC−braking operations.
Longer operation of self−ventilated motors at low speed.
Controller/system protection
l Drives can reach dangerous overspeeds (e.g. setting of
inappropriately high field frequencies):
The controllers do not offer any protection against these operating
conditions. For this, use additional components.