Design with plug:
-
Never disconnect the plug when energised! Otherwise, the plug can be destroyed.
-
Switch o power supply and disable inverter prior to disconnecng the plug.
•
Installed thermal detectors are no full protecon for the machine.
-
If required, limit the maximum current. Parameterise the inverter so that it will be switched o aer
seconds of operaon with I > I
rated
, especially if there is the danger of blocking.
-
The installed overload protecon does not prevent an overload under any condions.
•
The fuses are no motor protecon.
-
Use a current-dependent motor protecon switch.
-
Use the built-in thermal detectors.
•
Too high torques cause a fracon of the motor sha.
-
The maximum torques according to catalogue must not be exceeded.
•
Lateral forces from the motor sha may occur.
-
Align the shas of motor and driven machine exactly to each other.