Standard sengs
Parameter Value Comment
Designaon
Delivery Seng range
Parameter set name   [Text] File name of the parameter set without le
extension *.lsm
Output speed 1 0 -212.2 ... -42.6 rpm
0 rpm
42.6 ... 212.2 rpm
CCW rotaon = < 0 rpm
STOP = 0 rpm
CW rotaon = > 0 rpm
Lenze Smart motor with gearbox: The rao i
is taken into account in the calculaon of the
output speed.
Output speed 2 127.6 rpm
Output speed 3 0
Output speed 4 0
Output speed 5 0
Acceleraon me depending on the
order
[0.0 ... 20.0] s Acceleraon me t1 of the ramp generator
from 0 rpm to nmax [2600/i] rpm
Deceleraon me Deceleraon me t2 of the ramp generator
from nmax [2600/i] rpm to 0 rpm
Energy-saving funcon [O] Opmised for:
•
High dynamic performance
•
Maximum starng torque and torque
•
High speed accuracy
[On] Reduced energy absorpon in paral load
operaonal range.
Approx. 50 % of the maximum starng tor-
que are available.
Diagnoscs
Parameter Value Comment
Designaon Delivery Seng range
Peak load of the drive --- [0 … 250] % Last peak value of the medium thermal load
(maximum value in the last mains switching
cycle)
From rmwar version 03.00
Peak load of the brake resis-
tor
--- [0 … 250] % Last peak value of the medium thermal load
(maximum value in the last mains switching
cycle)
From rmwar version 03.00
Meters
Parameter Value Comment
Designaon Delivery Seng range
Elapsed-hour meter --- [0 ... 596523] h Total me of "Motor rotang"
Operang‐hour meter --- [0 ... 596523] h Total me of "mains ON"
Device data
Parameter Value Comment
Designaon Delivery Seng range
Material number depending on the
order
[number] Drive idencaon
Device types [Text]
Firmware version [Text]
Hardware Version [Text]
Motor [Text]
Gearbox [Text]
Rao [number]
Brake [Text]
Serial number [Text]