EasyManua.ls Logo

Lenze MSEMA 080-32 Series - Page 70

Lenze MSEMA 080-32 Series
80 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Logbook
Parameter Value Comment
Designaon
Delivery Seng range
Error message 1 (last) --- [text] Meaning: See fault eliminaon table
Error message 2 --- [text]
Error message 3 --- [text]
Error message 4 (earliest) --- [text]
Before switching on
That the drive does not show any visible signs of damage.
Is the mechanical xing o.k.?
Has the electrical connecon been implemented correctly?
Are all rotang parts and surfaces that may become hot protected against contact?
Is the featherkey radially secured during the test run without output elements?
Have all screwed connecons of the mechanical and electrical parts been ghtened?
Is it ensured that the cooling air can be freely supplied and discharged?
Has the PE conductor been connected correctly?
Have the protecve devices against overheang (temperature sensor evaluaon) been acvated?
Is the inverter parameterised correctly for the motor? (See operang instrucons for the inverter)
Are the electrical connecons ok?
Is the phase sequence of the motor connecon correct?
Is a protecon against contact provided in front of rotang parts and in front of surfaces that can get hot?
Is the contact of good electrical conducvity if a PE connecon on the motor housing is used?
Before inial switch-on, aer a longer downme or aer overhaul of the motor, check the following:
Measure the insulaon resistance; with values ≤1 kΩ per volt of the rated voltage, dry the winding.
Commissioning
Before switching on