EasyManua.ls Logo

Lenze Smart Motor m300 - Residual Hazards and Warnings

Lenze Smart Motor m300
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Residual hazards
Even if notes given are taken into consideraon and protecve measures are implemented,
the occurrence of residual risks cannot be fully prevented.
The user must take the residual hazards menoned into consideraon in the risk assessment
for his/her machine/system.
If the above is disregarded, this can lead to severe injuries to persons and damage to
property!
Product
Observe the warning labels on the product!
Dangerous electrical voltage:
Before working on the product, make sure there is no voltage applied to the power terminals!
Aer mains disconnecon, the power terminals will sll carry the hazardous electrical voltage for the me given next to the
symbol!
Electrostac sensive devices:
Before working on the product, the sta must ensure to be free of electrostac charge!
High leakage current:
Carry out xed installaon and PE connecon in compliance with:
EN IEC 61800−5−1 / EN IEC 60204−1
Hot surface:
Use personal protecve equipment or wait unl the device has cooled down!
Protecon of persons
The power terminals may carry voltage in the switched-o state or when the motor is
stopped.
-
Before working, check whether all power terminals are deenergized.
Voltages may occur on the drive components (e.g. capacive, caused by inverter supply).
-
Careful earthing in the marked posions of the components must be carried out.
There is a risk of burns from hot surfaces.
-
Provide protecon against accidental contact.
-
Use personal protecve equipment or wait unl the device has cooled down.
-
Prevent contact with ammable substances.
There is a risk of injury due to rotang parts.
-
Before working on the drive system, ensure that the motor is at a standsll.
There is a risk of accidental start-up or electric shock.
Motor protecon
Parameterize the product so that it will be switched o aer some seconds of operaon
with I > I
N
, especially if there is a risk of blocking.
-
The installed overload protecon does not prevent an overload under any condions.
The fuses are no motor protecon.
-
Use a current-dependent motor protecon switch.
-
Use the built-in temperature sensors.
Too high torques cause a fracon of the motor sha.
-
The maximum torques according to catalog must not be exceeded.
Lateral forces on the motor sha are possible.
-
Align the shas of motor and driven machine exactly to each other.
Informaon on project planning
Safety instrucons
Residual hazards
14

Other manuals for Lenze Smart Motor m300

Related product manuals