Example configurations
Leuze electronic CML 720i Ex 103
11.5 Example configuration – smoothing
11.5.1 Smoothing configuration (general)
Make the follo
wing settings for smoothing.
Example: Smoothing of four interrupted beams
Example: Inverted smoothing of four interrupted beams
11.5.2 Configuration of smoothing
via IO-Link interface
Assign
the desired value for smoothing.
Example: Smoothing of four interrupted beams
Example: Inverted smoothing of four interrupted beams
11.5.3 Configuration of smoothing
via CANopen interface
Assign
the desired value for smoothing.
Example: Smoothing of four interrupted beams
Example: Inverted smoothing of four interrupted beams
11.6 Example configuration - Cascading
11.6.1 Configuration of a cascading arrangement (general)
The following figure shows an example for a timing sequence of a
cascading arrangement with three light
curtains.
Smoothing settings Parameter
Smoothing -– less than i interrupted
beams are ignored
:
= 4 Beams are taken into account in the evaluation once
there are four or more interrupted beams
Smoothing settings Parameter
Inverted smoothing - less than i free
beams are ignored
:
= 4 Beams are taken into account in the evaluation once
there are four or more free beams
General configuration
(group 4)
Index 71, bit offset 8: = 4 Beams are taken into account in the evaluation once there are four or more
interrupted beams
General configuration
(group 4)
Index 71, bit offset 0: = 4 Beams are taken into account in the evaluation once there are four or more
free beams
General configuration
(module 3)
Index 2100 sub 03: = 4 Beams are taken into account in the evaluation once there are four or more
interrupted beams
General configuration
(module 3)
Index 2100 sub 4: = 4 Beams are taken into account in the evaluation once there are four or more
free beams