Example configurations
Leuze electronic CML 720i Ex 99
Configure pin 2 as area output.
Map pin 2 to configured area 1.
Possible additional area-to-pin configurations:
Map pin 2 to configured area 8.
Map the configured areas 1 and 8 (OR-linked) to the corresponding switching output.
11.2.2 Configuration of an area/output mapping via IO-Link interface
M
ap the beams to output pin 2 as follows.
Number of active beams for
area ON
Value: 32 32 1 1
Number of active beams for
area OFF
Value: 31 31 0 0
Switching behavior
Value: 0 = normal - light
switching (i.e., switching if
beams are free)
Output 1 if all beams are
free.
Output 0 if a beam is inter-
rupted or if more than a
beam are interrupted.
Output 0 if all beams are
free or 1 … 31 beams are
free.
Output 1 only if 32 beams
are interrupted.
Output 1 if all beams are
free or as long as 1 … 31
beams are free.
Output 0 if 32 beams are
interrupted.
Output 0 if all beams are
free.
Output 1 as soon as a
beam is interrupted.
Switching behavior
Value: 1 = inverted - dark
switching (i.e., switching if
beams are interrupted)
Output 0 if all beams are
free.
Output 1 if one or more
beams are interrupted.
OR function
Output 1 if all beams are
free or 1 … 31 beams are
free.
Output 0 only if 32 beams
are interrupted.
AND function
Output 0 if all beams are
free or as long as 1 … 31
beams are free.
Output 1 if 32 beams are
interrupted.
Output 1 if all beams are
free.
Output 0 as soon as a
beam is interrupted.
Description / variables
Configuration of digital inputs/outputs
Input/output selection Value: 0 = output Pin 2 functions as digital output
Function of the switching output Value: 1 = switching output (area 1 … 32) The switching output signals the logical states of beam
areas 1 … 32
Digital Output 2 Settings
Area mapping 32 … 1
(OR combination)
0b0000000000000000000000000000001 Every area is displayed as a bit.
Digital Output 2 Settings
Area mapping 32 … 1
(OR combination)
0b0000000000000000000000010000000
Digital Output 2 Settings
Area mapping 32 … 1
(OR combination)
0b0000000000000000000000010000001
Configuration of area 01
(group 14)
Index 100, bit offset 104: = 1 Area 01 active
Index 100, bit offset 96: = 0 Light switching
Index 100, bit offset 80: = 1 Start beam of the area
Index 100, bit offset 64: = 32 End beam of the area
Index 100, bit offset 48: = 32 Number of active beams for area ON
Index 100, bit offset 32: = 31 Number of active beams for area OFF