EasyManua.ls Logo

Leuze electronic MLC 500 - Calculation of Safety Distance S for Parallel Approach to the Protective Field

Leuze electronic MLC 500
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mounting
Leuze electronic MLC 510 24
6.1.3
Calculation of safety distanceS for parallel approach to the protective field
Calculation of safety distanceS for danger zone guarding
S [mm] = Safety distance
K [mm/s] = Approach speed for danger zone guarding with approach direction parallel to the protective field
(resolution up to 90mm): 1600mm/s
T [s] = Total time of the delay, sum from (t
a
+t
i
+t
m
)
t
a
[s] = Response time of the protective device
t
i
[s] = Response time of the safety relay
t
m
[s] = Stopping time of the machine
C [mm] = Additional distance for danger zone guarding with approach reaction H=height of the protec-
tive field, H
min
=minimum installation height permitted, but no smaller than0, d=resolution of
the protective device C=1200mm-0.4×H; H
min
=15×(d-50)
Calculation example
The danger zone in front of a machine with a stopping time of 140ms is to be safeguarded as close to the
floor height as possible using a horizontal safety light curtain as a replacement for a PS mat. Installation
heightH
min
can be=0 - additional distanceC to the safety distance is then 1200mm. The shortest possible
safety sensor is to be used; the first value to be selected is to be 1350mm.
The receiver with 40mm of resolution and 1350mm protective field height has a response time of 13ms,
an additional relay interface a response time of 10ms.
Ä Calculate safety distanceS
RO
using the formula acc. to ISO13855.
K [mm/s] = 1600
T [s] = (0.140+0.013+0.010)
C [mm] = 1200
S [mm] = 1600mm/s×0.163s+1200mm
S [mm] = 1461
The safety distance of 1350mm is not sufficient; 1460mm are necessary.
This is why the calculation is repeated with a protective field height of 1500mm. The response time is now
14ms.
Ä Re-calculate safety distanceS
RO
using the formula acc. to ISO13855.
K [mm/s] = 1600
T [s] = (0.140+0.014+0.010)
C [mm] = 1200
S [mm] = 1600mm/s×0.164s+1200mm
S [mm] = 1463
A suitable safety sensor has been found; its protective field height is 1500mm.