Mounting
Leuze electronic MLC 520 27
2
4
1
3
1 Transmitter1
2 Receiver1
3 Transmitter2
4 Receiver2
Fig.6.4: Optical crosstalk between adjacent safety sensors (transmitter1 influences receiver2) due to incorrect
mounting
NOTICE
Possible impairment of the availability due to systems mounted close to each other!
The transmitter of one system can influence the receiver of the other system.
Ä Prevent optical crosstalk between adjacent devices.
Ä Mount adjacent devices with a shield between them or install a dividing wall to prevent mutual interfer-
ence.
Ä Mount the adjacent devices opposite from one another to prevent mutual interference.
2
4
1
3
1 Receiver1
2 Transmitter1
3 Transmitter2
4 Receiver2
Fig.6.5: Opposite mounting
In addition to design characteristics, the safety sensor offers functions that can remedy this:
Selectable transmission channels (see chapter 4.3 "Transmission channel changeover")