Electrical connection
Leuze electronic MLC 530 60
Figure 7.9: Operating mode 2: circuit diagram example of linkage of electronic safety-related switching
outputs for the combined monitoring of access points and areas
1 MLC 500 transmitter
2 MLC 530 receiver
3 AC-SCM8 sensor connection module
4 Multiple Light Beam Safety Device, MLD510-RT2 transceiver and MLD-M002 Deflecting Mirror
5 CB-M12-X000E-2GF/GM connection cable
6 CB-M12-X000E-8GF connection cable
7 MSI-SR4 Safety Relay with RES and EDM
8 CB-M12-X000E-5GF/GM connection cable
Figure 7.10: Operating mode 2: connection example with MLC 530 and MLD 510 for combining point of
operation and access guarding
7.5 Operating mode 3
The following functions are summarized in function groups (FG) which can be selected by switching
between IN4 and IN8. In FG1, fixed and/or floating blanking can be selected, reduced resolution and Singl-
escan are pre-set and permanent and there is an option of integrating a contact-based safety circuit. In
VIN2
7
IN3
3
VIN1
2
FE
-A2
MLC530R
IN4
4
IO1
1
+ 24V
FE
0V
+ 24V
FE
0V
OSSD2
5
OSSD1
8
IN8
6
WH
PK
GN
BN
BU
YE
GY
RD
VIN1
1
RNG
4
VIN2
3
FE
5
-A1
MLC500T
n.c.
2
WH
GY
BU
BN
BK
+24V
1
OSSD2
4
0V
3
FE
-A3
MLD510RT
OSSD1
2
WH
BK
BU
BN
1
2
3
5
6
7
4
8
X1
X2
X3
X4
X5