Electrical connection
Leuze electronic MLC 530 61
FG2, fixed blanking can be activated, DoubleScan is pre-set and permanent and there is an option of inte-
grating a contact-based safety circuit.
Fixed blanking, see chapter 4.7.1 „Fixed blanking“
Floating blanking (see chapter 4.7.2 „Floating blanking“) as well as the combination of fixed and
floating blanking (see table 7.7)
SingleScan, DoubleScan can be selected, see chapter 4.5 „Scan mode“
Integration of contact-based safety circuit possible, see chapter 4.6.1 „Contact-based safety circuit“
Reduced resolution (reduction by 1 beam) possible, see chapter 4.7.4 „Reduced resolution“
Permanent settings which cannot be changed by control signals:
Internal start/restart interlock deactivated
Table 7.7: Operating mode 3 pin assignment with both FG1 and FG2 function groups
Teach blanking by opening the bridge between pin 1 and pin 3 with a teach key switch and ap-
plying a voltage of +24 V to pin 1 and a voltage of 0 V to pin 3 (see table 7.5).
Pin FG1: fixed and float-
ing blanking as well
as reduced resolution
and SingleScan
FG2: fixed blanking and
DoubleScan
Teaching the blank-
ing (open bridge,
apply voltage)
Integration of a con-
tact-based safety cir-
cuit in FG1 and FG2
1 (IO1) Bridge to pin 3 (IN3) Bridge to pin 3 (IN3) +24 V
3 (IN3) Bridge to pin 1 (IO1) Bridge to pin 1 (IO1) 0 V
4 (IN4) +24 V 0 V Normal closed con-
tact between supply
voltage or control out-
put and pin
8 (IN8) 0 V +24 V Normal closed con-
tact between protec-
tive field inputs and
device
2 0 V 0 V 0 V 0 V
7 +24 V +24 V +24 V +24 V
5 OSSD1 OSSD1 OSSD1 OSSD1
6 OSSD2 OSSD2 OSSD2 OSSD2