PROFIsafe and PROFINET
Leuze electronic GmbH + Co. KG RSL 420P 104
Module Description Input data
[Byte]
Output
data
[Byte]
[M7]
PROTECTIVE_FUNC-
TION_A_VIOLATION
see chapter 11.5.9 "Module
[M7] – PROTECTIVE_FUNC-
TION_A_VIOLATION"
Information on protective field interruption
or warning field interruption of protective
function A
8 0
[M8]
PROTECTIVE_FUNC-
TION_B_VIOLATION
see chapter 11.5.10 "Module
[M8] – PROTECTIVE_FUNC-
TION_B_VIOLATION"
Information on protective field interruption
or warning field interruption of protective
function B
8 0
11.5.2
Project modules for DAP2
Modules [M11]…[M17]
• For devices with M12 connection unit (CUM12):
• DeviceID: 0x0011
• Textual designation for configuration:
RSL400PM12V2
• For devices with AIDA connection unit for copper cables (CUAIDA):
• DeviceID: 0x0012
• Textual designation for configuration:
RSL400PAIDAV2
• For devices with AIDA connection unit for fiber-optic cables (CUAIDA-OF):
• DeviceID: 0x0013
• Textual designation for configuration:
RSL400PAIDA-OFV2
• For devices with connection unit with L-coded M12 connectors/sockets for the voltage supply
(CU4M12):
• DeviceID: 0x0016
• Textual designation for configuration:
RSL400P4M12V2
Module Description Input data
[Byte]
Output
data
[Byte]
[M11]
SAFE_SIGNAL_PS2V4
see chapter 11.5.11 "Module
[M11] ‑ SAFE_SIGNAL_PS2V4"
For PROFIsafe version2.4:
Safe module containing the safe input and
output signals.
3 7
[M11]
SAFE_SIGNAL_PS2V6
see chapter 11.5.12 "Module
[M11] ‑ SAFE_SIGNAL_PS2V6"
For PROFIsafe version2.6:
Safe module containing the safe input and
output signals.
2 6
[M12]
SYSTEM_STATUS
see chapter 11.5.13 "Module
[M12] ‑ SYSTEM_STATUS"
General information on the status of the de-
vice and safety functions.
Simple system diagnostics is possible.
6 0