Module [M12] ‑ SYSTEM_STATUS
Module ID:0x00000004
Submodule ID:0x0000000C
Description
The module supplies information on the current operating mode of the RSL400 and on possible error
causes. It contains the most important diagnostic information for the total system and the individual protec-
tive functions. Simple device diagnostics is made possible by integrating this module.
Input data structure module SYSTEM_STATUS
Byte in
non-safe
telegram
Byte in
mod-
ule
Bit Data
type
Signal name Value
‘0‘
Value
‘1‘
Safe Description
0 0 0…7 Byte OP-MODE N Current operating
mode of the
RSL400
PROFIsafe
0: No configura-
tion defined
1: Safety monitor-
ing mode
2: Simulation
mode
1 1 0 Bit A-ACTIVE N Y N Protective func-
tionA active / con-
figured
1…3 Bit Reserve
4 Bit B-ACTIVE N Y N Protective func-
tionB active / con-
figured
5…7 Bit Reserve
2 2 0 Bit ERROR OFF Mes-
sage
N Collective mes-
sage: error (safety
bit0)
1 Bit ALARM OFF Mes-
sage
N Collective mes-
sage: warning
(safety bit 1)
2 Bit SCREEN OFF Mes-
sage
N Contamination dis-
play for optics
cover
(Warning and
switch-off)
3 Bit FIELD PAIR OFF Mes-
sage
N Collective mes-
sage for field pair
changeover error
4 Bit MODE-PARK NOT
PARKE
D
PARKE
D
N Park mode con-
firmed
5…7 Bit Reserve

Table of Contents