Device description
Leuze electronic GmbH + Co. KG RSL 420P 14
All safety sensors of the RSL420P series are equipped as follows:
• Laser scanner with the range class S, M, L or XL:
Operating range
class
Operating range [m]
S 3.00
M 4.5
L 6.25
XL 8.25
• 24-digit alphanumerical display
• Integrated electronic spirit level for aligning the safety sensor
• LED indicator
• USB interface
NOTICE
Ä Use the USB connection only temporarily for configuration or diagnosis of the safety sensor.
Ä For permanent connection, connect the safety sensor to the Ethernet connection of the con-
nection unit.
• Connection unit:
• Configuration memory
• Ethernet connection for communication and configuration with the PC/laptop
3.1 Device overview
The following table provides an overview of the possible uses, features and functions of the RSL400 safety
sensors with PROFIsafe interface.
Tab.3.1: Device overview
RSL420P RSL450P
RSL455P
Stationary danger zone guarding x x
Mobile danger zone guarding x x
Point of operation guarding x x
Safe output signals 1bit 4bit
Additional output signals See description of the process data
Number of changeover-capable protective/warning field
pairs
10 100
Four field mode (quads) - x
Measurement data output optimized for vehicle naviga-
tion
- Only RSL 455P
USB interface x x
Bluetooth interface x x