Technical data
Leuze electronic GmbH + Co. KG RSL 420P 142
Tab.16.8: Device connection and PROFIsafe/communication connection
CU400P-3M12 Device connection:
M12 connector, 4-pin, standard, A-coded
Connection socket PROFIsafe/communication:
M12 socket, 4-pin, D-coded
CU400P-4M12 Device connection:
M12 connector/socket, 5-pin, L-coded
Connection socket PROFIsafe/communication:
M12 socket, 4-pin, D-coded
CU400P-AIDA Device connection:
PROFINET push-pull 24V
Connection socket PROFIsafe/communication:
PROFINET RJ45 push-pull IEC61076-3-117 var.14
CU400P-AIDA-OF Device connection:
PROFINET push-pull 24V
Connection socket PROFIsafe/communication:
PROFINET SCRJ push-pull ISO/IEC61754-24-2
Tab.16.9: Inputs and outputs
Properties Max. output current I
a
Min. input current I
e
Typical connection
components
EA1, EA2 20mA ---
Signal definition:
High/logical 1 16-30V
Low/logical 0 <3V
Tab.16.10: Reaction time
Minimum Typical Maximum
Response time (T
SC
) 80ms (2 scans) 1000ms (25 scans)
PROFIsafe processing and output
(DAT
output
)
47 ms
PROFIsafe watchdog time (T
WD
) DAT
output
+ T
PS-MASTER
+ 4*T
PN
Tab.16.11: PROFINET
PROFINET device Device acc. to SpecV2.3.4
GSDML GSDML acc. to SpecV2.3.4
Profile PROFINET/PROFIsafe
Conformance class Class C
Network load class Class III
Security level Security level1
Switch IRT-ready 2-port switch acc. to IEEE 802; integrated in connection
unit
Port properties Auto-Negotiation
Auto-Polarity
Auto-Crossover
I&M I&M 0-4