EasyManua.ls Logo

Leuze electronic RSL 420P - Sensor Functions; Authorization Concept

Leuze electronic RSL 420P
161 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Functions
Leuze electronic GmbH + Co. KG RSL 420P 34
5 Functions
The functions of the safety sensor must be matched to the respective application and its safety require-
ments. You can activate/deactivate the functions and adapt them using parameters. You configure the
functions with the help of the configuration and diagnostics software (see chapter 9 "Configuring the safety
sensor").
You configure the functions of the safety sensor in the software as configuration projects.
In each configuration project you determine the protective function and the configurable field pairs via
the selected function mode.
The changeover-capable protective/warning field pairs for the selected function mode are defined in
configuration banks.
You determine the resolution, the start-up behavior, the response time and, where applicable, the vehi-
cle speed together for all protective/warning field pairs of a configuration bank.
5.1 Authorization concept of safety sensor
User management allows target-group-oriented communication between the software and the safety sen-
sor. Which functions are available depends on the selected access level of the user. For information on
the software and on user management (see chapter 4 "Configuration and diagnostic software SensorStu-
dio").
Changing the safety configuration as well as the communication and diagnostics settings of the sensor
is only permitted for certain access levels.
Installation and operation of the software do not depend on the access level of the user.
The following access levels are available:
Tab.5.1: Access levels and functions available
Access level Functions
Observer Display the measurement contour
Upload and display configuration data from the safety sensor
Display status information from the safety sensor
Display diagnostics list
Customize display
Display and evaluate the measurement contour
Load configuration data from the safety sensor
Load status information from the safety sensor
Display diagnostics list
Create service file
Reset password
Expert In addition to the functions of the Observer
Load the signed safety configuration from a file and transfer/download to
the safety sensor
Transfer changed communication and diagnostics settings from the PC
to the safety sensor
Print configuration data incl. protective/warning fields
Calibrate optics cover

Table of Contents

Related product manuals