Electrical connection
Leuze electronic GmbH + Co. KG RSL 420P 73
8.6 Connection unit CU400P-AIDA-OF
1 AIDA sockets, PROFINET, push-pull, 5-pin, voltage supply via copper cable
2 AIDA socket, PROFINET, SCRJ push-pull, 2-pin, PROFINET/PROFIsafe communication via fiber-optic cable,
input
3 AIDA socket, PROFINET, SCRJ push-pull, 2-pin, PROFINET/PROFIsafe communication via fiber-optic cable,
output
Fig.8.10: Device with connection unit CU400P-AIDA-OF
Voltage supply
The safety sensor is supplied with voltage via two 5-pin PROFINET AIDA push/pull connections for copper
cables. The scanner is supplied from mains L1/N1.
Fig.8.11: Pin assignment PROFINET AIDA push-pull, 5-pin
Tab.8.7: Pin assignment for voltage supply
PIN Signal Comment
1 L1 24VDC (US1+)
2 N1 0VDC (US1-)
3 L2 24VDC (US2+)
4 N2 0VDC (US2-)
5 GND/shield It is also possible to operate the device with unshielded interconnection cables.
The use of shielded interconnection cables is, however, recommended.
• The current load of the connections must not exceed 16 A/pin.
NOTICE
Ä Lay the cables for the linear topology and the tap in the PROFINET controller in such a way
that short circuits are prevented.