Configuring the safety sensor
Leuze electronic GmbH + Co. KG RSL 420P 86
9.8 Selecting access level
Using the device manager (DTM) you can change the access level of the user, if necessary (see chapter
5.1 "Authorization concept of safety sensor").
Ä Click in the DTM menu bar on the Change access levelbutton (
).
ð The Change access level dialog box opens.
Ä In the Authorization list, select the item Engineer, Expert or Observer and enter the default password
or the password defined for the individual user (see chapter 4.5.6 "SETTINGS").
• Default password for Engineer: safety
• Default password for Expert: comdiag
Ä Confirm with [OK].
9.9 Reset safety configuration
The device manager (DTM) can be used to reset the safety configuration to the default configuration (one
protective function, no restart).
Ä In the DTM menu bar, click the [Reset safety configuration] button.
ð Users with the access level Engineer can additionally transfer the changed safety configuration to the
safety sensor (see chapter 9.7 "Transferring configuration project to safety sensor").