PROFIsafe and PROFINET
Leuze electronic GmbH + Co. KG RSL 420P 93
11.3 Integrating in a PROFIsafe network
11.3.1
Network topology
RSL400 PROFIsafe devices can be integrated in the following network topologies:
• Star
• Line
• Ring
11.3.2
Addressing
The following information is needed for the RSL400 PROFIsafe to exchange data with other devices in the
network:
• PROFINET name
• Unique IP address
• Subnet mask
• If applicable, the IP address of the router.
You can assign the data to the RSL400 PROFIsafe in the following ways:
• SensorStudio configuration software
• Configuration software for a PROFINET network
• PROFINET control
NOTICE
Storing IP address permanently in the device
Ä If you store the IP address permanently in the RSL400 PROFIsafe, it is retained even after
the device is switched off.
Ä The IP address can, however, be changed by the PROFINET control.
11.3.3
Configuring the PROFINET control
NOTICE
For further information on configuring the PROFINET control, see see chapter 11.4 "Configuring
for the Siemens TIA Portal".
Proceed as follows to configure the PROFINET control:
Ä Load the GSDML file in the configuration software of the control.
Ä Select the desired device in the hardware catalog, e.g., use the search function and enter RSL400 or
Leuze.
Ä Add the device to the project and connect the device to the control.
Ä Select the PROFINET project modules according to the process image (see chapter 11.5 "PROFINET
project modules").
Ä Assign a unique PROFINET device name.
Ä Set the PROFIsafe parameters.
Tab.11.1: PROFIsafe parameters
Parameter Meaning Setting
F_SIL Safety integration level of the safety laser
scanner
SIL2 (not changeable)
F_Block_ID ’0’ (not changeable)
F_Par_Version PROFIsafe operating mode ’0’ (not changeable)