Lexicon MC-12HD Serial Communications Protocol
7.1.4.3 HOST Response
The MC-12HD does not expect any response from the HOST.
7.1.4.4 Defaults
The following Parameters Notifications are Enabled in the MC-12HD default state:
Parameter MC-12HD Parameter Name
Current Mode
PARAM.MAIN.EFFECT
Main Zone Mute
PARAM.MAIN.MUTE
Main Zone Volume
PARAM.MAIN.VOLUME
Main Zone Balance
PARAM.MAIN.BALANCE
Main Zone Input Selection
PARAM.MAIN.INPUT
Zone 2 Input
PARAM.ZONE.INPUT
Zone 2 Volume
PARAM.ZONE.VOLUME
Zone 2 Balance
PARAM.ZONE.BALANCE
Zone 2 Mute
PARAM.ZONE.MUTE
Bass
PARAM.MAIN.BASS
Treble
PARAM.MAIN.TREBLE
Loudness
PARAM.MAIN.LOUDNESS
Tilt
PARAM.MAIN.TILT
Menu Background On/Off
PARAM.OSD.BACKGND
7.2 Acknowledgment Packets
Acknowledge and No Acknowledge packets are used to communicate transmission, packet and data
validation status. Both the HOST and MC-12HD can transmit and receive these packets.
7.2.1 Acknowledge
7.2.1.1 Packet Description
Application Header:
Command DC_ACK 0xE0
Data Count 1 0x01
Application Data:
Data[0] Command nn