Lexicon MC-12HD Serial Communications Protocol
7.3.2.1 Command Packet Description
Application Header:
Command DC_CMD_RESTORE_DEFAULTS 0x13
Data Count 0 0x00
Application Data:
N/A
7.3.2.2 MC-12HD Response
The MC-12HD will reset, clear any saved system and effect parameters in Nonvolatile RAM, and restore
the factory default system and effect parameters. After reset the MC-12HD will go through a soft power-
up initialization. This includes transmitting the “Wakeup Notification Packet”.
7.3.3 Get Custom Name
Request to MC-12HD for the custom name. MC-12HD will respond with “Custom Name Packet”.
7.3.3.1 Command Packet Description
Application Header:
Command DC_CMD_GET_CUST_NAME 0x2B
Data Count 0 0x00
Application Data:
N/A
7.3.3.2 Data Description
N/A
7.3.3.3 Custom Name Response Packet
Application Header:
Command DC_RESP_CUST_NAME 0x89
Data Count
Number of Characters in
CustomName + 1
nn
Application Data:
Data[0]- Data[DataCount-1] CustomName ch ch ch … 0x00
7.3.3.4 Data Description
CustomName:
Data Type: Null (0x00) terminated ASCII character string.
Max Length: CUSTOM_NAME_LENGTH defined in
Appendix E Protocol Constants.
7.3.4 Set Custom Name
Sets the Custom Name that can be displayed when the unit powers up.