EasyManua.ls Logo

Lexicon MC-12HD - MC-12 HD Set Zone2 Left;Right Balance; MC-12 HD Get Input Name by ID

Lexicon MC-12HD
135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Lexicon MC-12HD Serial Communications Protocol
7.3.28 MC-12HD Set Zone2 Left/Right Balance
Commands MC-12HD to set the Zone 2 balance to the value in this packet.
7.3.28.1 Packet Description
Application Header:
Command MC_CMD_SET_ZONE2_BALANCE 0x46
Data Count 1 0x01
Application Data:
Data[0] Value nn
7.3.28.2 Data Description
Value:
Data Type: Signed 8 bit integer (2’s compliment)
Max: +16 (0x10) (Full Right)
Min: -16 (0xF0) (Full Left)
7.3.28.3 MC-12HD Response
The MC-12HD will assign the value from the packet to the Zone 2 balance.
7.3.28.4 Data Validation
If a value is passed that exceeds the maximum value of that parameter the MC-12HD will ignore the
command and transmit a NAK command with an error code DC_INVALID_DATA.
7.3.29 MC-12HD Get Input Name by Id
This command is a request to MC-12HD for the custom input name. MC-12HD will respond with “Input
Name Packet”.
7.3.29.1 Command Packet Description
Application Header:
Command MC_CMD_GET_INPUT_NAME 0x47
Data Count 1 0x01
Application Data:
Data[0] InputId nn
7.3.29.2 Data Description
InputId:
Data Type: Unsigned 8 bit Integer
Definition/Conversion:
Appendix D MC-12HD Input Ids
7.3.29.3 Data Validation:
The InputId must be a valid Input number. If it is not the MC-12HD will respond with a NAK packet and
error code DC_INVALID_INPUT.
33