Diagnostic information 2-103
4062
936.10 Main drive motor
assembly failure
No halls detected at
motor start.
Motor = type 0
The main drive motor assembly
may be faulty or has failed.
1. Check all connections on
the system card assembly.
2. Check all connections on
the main drive motor
assembly.
3. Replace the main drive
motor assembly. Go to
“Output cover assembly
removal” on page 4-53.
4. Replace the system card
assembly if problem
remains. Go to “System
card assembly removal”
on page 4-75.
936.11 Main drive motor
assembly failure
No halls detected at
motor start.
Motor = type 1
The main drive motor assembly
may be faulty or has failed.
1. Check all connections on
the system card assembly.
2. Check all connections on
the main drive motor
assembly.
3. Replace the main drive
motor assembly. Go to
“Output cover assembly
removal” on page 4-53.
4. Replace the system card
assembly if problem
remains. Go to “System
card assembly removal”
on page 4-75.
936.20 Main drive motor
assembly failure
Failed to stop within
timeout.
Motor = type 0
The main drive motor assembly
may be faulty or has failed.
1. Check all connections on
the system card assembly.
2. Check all connections on
the main drive motor
assembly.
3. Replace the main drive
motor assembly. Go to
“Output cover assembly
removal” on page 4-53.
4. Replace the system card
assembly if problem
remains. Go to “System
card assembly removal”
on page 4-75.
936.21 Main drive motor
assembly failure
Failed to stop within
timeout.
Motor = type 1
The main drive motor assembly
may be faulty or has failed.
1. Check all connections on
the system card assembly.
2. Check all connections on
the main drive motor
assembly.
3. Replace the main drive
motor assembly. Go to
“Output cover assembly
removal” on page 4-53.
4. Replace the system card
assembly if problem
remains. Go to “System
card assembly removal”
on page 4-75.
Error
code or
message
Error contents Description/Action Possible repair actions