3-18 Service Manual
4022-XXX
Configuration ID
The printer code uses the Configuration ID to determine the characteristics of certain
areas of the printer that cannot be determined using hardware sensors. The
Configuration ID is set when the printer is manufactured.
The Configuration ID can be set using NPA or the operator panel. Manufacturing uses
NPA to set the Configuration ID for the first time. The CE uses the operator panel to reset
the configuration ID if the engine card (which contains the NVRAM) is replaced as part of
the service action. The CE should get the appropriate ID from the table listed below. After
a valid ID is set using either method (that is invalid IDs are ignored), the printer
automatically PORs to activate the new setting.
Common Configuration ID’s for the Lexmark W812:
If the printer firmware detects that the configuration ID has not been set, or if an invalid
configuration ID has been detected, the firmware automatically uses the configuration ID
value defined for the printer standard model. The printer posts on the operator panel a
status warning indicating the configuration ID is invalid. This warning remains on the
display until a valid configuration ID is set using NPA or the operator panel.
Operating Voltage
Operator Panel
Language Set
Configuration ID
100 V Code Page 850 and
Katakana
000101
110 V Code Page 850, ISO
Cyrillic, ISO Latin 2 and
ISO 5
000189
220 V Code Page 850, ISO
Cyrillic, ISO Latin 2 and
ISO 5
10018A