Connector Locations 5-21
4025-XXX
BD5 HVPS↔I/O PWB
The following table shows the signal names for this BD:
HVPS Output
Signal Name Description
DBAC$CLK Controls AC to the Mag Roll
DBAC$RMT Varies the DB AC voltage
DBAC$ON Varies the DB AC voltage
DBDC$RMT Varies the DB DC voltage
BCRAC$CLK Controls AC to the BCR
BCRAC$ON Switches AC to the BCR
BCRDC$RMT Varies the BCR DC voltage
DTS$ON Switches AC to the Detack Saw
BTR$SEL Switches DC voltage polarity to the BTR
BTR$ON Switches the BTR
BTR$RMT Controls voltage to the BTR
BTR##MON Monitors BTR voltage level
AGND Ground
+24VSQ 24VDC supplied through the interlock switch
FB$ON Switches Fuser Bias. Used on only DADF/IIT install.
FB$SEL Switches Fuser Bias polarity
Terminal Output Voltage or Current
BCR BCR(AC) 2.2mA (Average)
BCR(DC) -470 VDC
DB DB(AC) 1.78kVp-p
DB(DC) -350 VDC
BTR TR(+) 1.6kV, 3kV or 4.4kV (Reference)
TR(-) -1.5 VDC
DTS DTS -2.13k VDC

Table of Contents