Repair information 4-67
7013-XXX
Paper input and duplex sensor assembly removal
1. Remove the right side printer cover. See “Right side printer cover removal” on page 4-73.
2. Remove the duplex. See “Duplex removal” on page 4-16.
3. Remove the two screws (A) from the sensors.
4. Disconnect the sensor cable (B) from J30 on the controller board.
5. Remove the paper input and duplex sensor assembly.
A
B