Repair information 4-27
7011-2xx
Input sensor #2 (manual feed) removal
1. Open the right side cover. See “Right side cover removal” on page 4-7 for more information.
2. Disconnect the sensor cable at J18 on the controller card (front, top of card).
3. Remove the paper tray.
4. Carefully place the MFP on its back with the bottom of the MFP facing you. Remove the screw (A) beside
the left pick tire.
5. Remove the sensor and its attached cable.
6. Re-install the new sensor in the same orientation as the old. The flag should be spring loaded against the
leading edge of an advancing sheet.
7. Verify the cable is captured and away from the paper path.