Diagnostic information 2-89
7462
922.30 After hot roll lamp
detection, did not roll
over to steady state
control in time.
Fuser type = 2
The control code has gotten
lost (this should really be a
software error.
Turn the machine off/on.
922.31 Fuser warm-up failure
Fuser type = 2
The fuser hot roll did not reach
operating temperature within
new enhanced control.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Check all connections on
the fuser and LVPS card
assembly.
4. Replace the fuser unit
assembly if problem
remains. Go to “Fuser unit
assembly removal” on
page 4-16.
5. Replace the LVPS card
assembly if problem
remains. Go to “LVPS card
assembly removal” on
page 4-45.
922.32 Fuser warm-up failure
Fuser type = 2
The fuser hot roll does not
reach operating temperature
after increasing interpage gap.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Check all connections on
the fuser and LVPS card
assembly.
4. Replace the fuser unit
assembly if problem
remains. Go to “Fuser unit
assembly removal” on
page 4-16.
5. Replace the LVPS card
assembly if problem
remains. Go to “LVPS card
assembly removal” on
page 4-45.
922.50 Fuser warm-up failure
Fuser type = 1
Fuser page count has
exceeded life.
The fuser hot roll failed to
reach target temperature.
Replace the fuser unit
assembly if problem remains.
Go to “Fuser unit assembly
removal” on page 4-16.
922.52 Fuser warm-up failure
Fuser type = 1
Fuser page count has
exceeded life.
The fuser hot roll does not
reach the “beginning lamp
detection” parameter in the
specified time.
Replace the fuser unit
assembly if problem remains.
Go to “Fuser unit assembly
removal” on page 4-16.
Error
code or
message
Error contents Description/Action Possible repair actions