EasyManua.ls Logo

Lexmark X792 7562-4xx - XX-Motor (Fuser) Error Service Check

Lexmark X792 7562-4xx
855 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diagnostic information 2-77
7562
Go Back
Previous
Next
120.xx—Motor (fuser) error service check
Step Questions / actions Yes No
1 Turn the printer off, open the system board
shield, and remove the RIP card shield.
Check the cable in connector JYF1 (BLDC Y
& Fuser cable) for proper connection to the
system board.
Is the cable properly connected?
Go to step 2. Reseat the cable.
2
Check the cable for damage.
Is the cable damaged?
Replace the BLDC Y &
Fuser cable. See “EP
drive assembly removal
on page 4-54.
Go to step 3.
3
Remove the rear cover. See “Rear cover
removal” on page 4-23.
Check the cable (B) for proper connection to
the fuser motor.
Is the cable properly connected?
Go to step 4. Reseat the cable.
4
Is the BLDE Y & Fuser cable damaged? Replace the BLDC Y &
Fuser cable. See “EP
drive assembly removal
on page 4-54.
Go to step 5.
B

Table of Contents